Commit Graph

3912 Commits (a262ad91e82729b661049f24a5d5968d08ce161c)

Author SHA1 Message Date
Hannes Reinecke a262ad91e8 99base: Add chown binary
nvidia driver needs this via modprobe script.
Needs to do change the group after a device node got created.
Add chown instead of chgrp which can also change the owner of a file.

Ask Stefand Dirsch <sndirsch@suse.de> for details.

Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:37 +01:00
Hannes Reinecke 681462eca8 40network: add missing _arch variable declaration
The module_setup.sh script was missing an '_arch' declaration,
causing network not to be installed on s390.

Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:37 +01:00
Thomas Renninger 9492008435 Enhance suse.conf and debug module example with SUSE-specific settings
SUSE is using specific settings for dracut, so add them
to the suse.conf.example file.

Add vi and find to the debug module add some help text to the suse.conf
file when and how to use it.

Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:37 +01:00
Hannes Reinecke 22e837b645 95fcoe: start lldpad separately
lldpad is a system-wide process, which must be started only once.
So we should be separate it from fcoe-up, as it might be called
several times.

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Hannes Reinecke 0a68a26cff 95fcoe: skip VLAN devices in fcoe-up
DCB & fipvlan can only be called on real devices, not VLAN
ones. So skip any VLAN devices which might been added to the
list of network interfaces.

References: bnc#878583

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Hannes Reinecke 8b257fcc86 95fcoe: Store current configuration in dracut cmdline
When running with --hostonly-cmdline we should be storing
the current configuration in /etc/cmdline.d so that dracut
will be configure the system automatically.

References: bnc#877288

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Hannes Reinecke c64a94caa9 95fcoe: update fcoe interface check
The 'create' sysfs entry has been removed for newer fcoe modules,
so just check if the module directory exists.

References: bnc#877288

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Thomas Renninger 8d40852e8c dracut: Do not stop installing drivers if one fails
--add-drivers and --filesystems kernel drivers are added via:
instmods -c
The check option makes the function return if one driver could not get
installed without trying to install further drivers which is bad.

The user is still informed ($_silent is by default no), but all modules
passed to instmods are tried to be loaded, even if one fails.

Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Hannes Reinecke cd72830807 95iscsi: parse output from iscsiadm correctly
Due to some obsure reason the IFS parameter is not set correctly
when evaluating get_ibft_mod(). So change the parsing to not rely
on IFS altogether.

References: bnc#886199

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Thomas Renninger 206345ce9b nfs: Add ip=... and root=nfs... parameters to internal dracut
cmdline

If the rootfs is an nfs mount, also know as nfsroot, add the correct
parameter to the dracut cmdline.

Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Thomas Renninger 4d25892179 dracut.usage.asc: Remove distro specific help from manpage
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Thomas Renninger 6df523517f dracut.sh: Fix UUID= fstab parsing in case --mount option is passed
Dracut parses /etc/fstab when --mount is option is passed (e.g. kdump).

In host_devs variable the real block device must be stored, not UUID=
There are other /etc/fstab syntax possibilities we now warn that they
are not correctly parsed. This will be fixed by another patch
when there is time to test this properly.

Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Thomas Renninger 118ca9ecfc dracut.sh: Avoid duplicate devices in host_devs
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
jloeser 3838dc47c3 Check for logfile (--logfile option) and create it if necessary
If a logfile is passed to dracut via --logfile option and doesn't
exist, dracut doesn't create it and logs nothing. Instead, dracut
should try to touch the file and print a warning if creating fails.

References: bnc#892191
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Thomas Renninger 5c84d51b3f 90lvm: Install dm-snapshot module
bnc#888530

Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Thomas Renninger 517d27a75f 99base: Increase initqueue timeout in non systemd case
In case of systemd is used the timeout already is set to 180s, compare
with file: modules.d/98systemd/dracut-initqueue.sh

Do the same if systemd is not used, e.g. in kdump case.

Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Hannes Reinecke 3ae60e559f Handle module alias properly
Some modules (like ext4) provide aliases by which the modules
can be accessed, too. But when using aliases directly dracut
fails to include the correct module. So translate the alias
into the correct module name before checking the module.

References: bnc#886839

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Hannes Reinecke 7c2311660f 99base: warn on invalid command for initqueue
When 'initqueue' is called with an invalid command it'll generate
invalid job scripts. This will lead to confusing error messages
later on.
So abort in these cases and print out a warning.

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Thorsten Behrens bd44831b82 Generate fallback mount unit for root filesystem
If kernel cmdline has no root= provided, *and* the initrd carries
a default value, create a systemd mount unit to have it available
in /sysroot

References: bnc#855258

Signed-off-by: Thorsten Behrens <tbehrens@suse.com>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Thorsten Behrens e3eec4b8a2 Align dev_unit_name() with systemd's function.
Add more corner cases from systemd's
unit_name_from_path_instance() C function.

Signed-off-by: Thorsten Behrens <tbehrens@suse.com>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Hannes Reinecke fe273e3901 Print stored dracut commandline during initramfs build
When generating the initramfs we should be printing out the
generated dracut commandline used for booting.
This will simplify debugging.

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Hannes Reinecke 3244bf5981 Do not call 'lvm' for non-LVM device-mapper devices
If a device-mapper device is not created by LVM it's pointless
to call any 'lvm' programs got extract details; they'll be
failing anyway. So check the UUID before calling 'lvm'.
This speeds up initrd creation and avoids I/O errors on
multipath devices.

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Hannes Reinecke 56663e7e32 Implement 'rd.timeout' to modify the device timeout
When generating units for devices the administrator might
want to use a different timeout than the default.
So implement a new parameter 'rd.timeout' for this.

References: bnc#878770

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Thomas Renninger f34a2ef14d iscsi: iscsi.initiator and others can and must only show up once
Make sure duplicates of iscsi.initiator vanish.
Only get one rd.iscsi.* paramter value. If getargs is used and several
parameters are parsed, one gets two values separated by whitespace in a
variable which breaks later code and is not suppported.

Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Hannes Reinecke c4d8793c67 95iscsi: generate commandline for software iscsi
When installing on an software iscsi root we need to generate
the correct commandline, otherwise the system cannot boot.

References: bnc#880108
Patch: 0093

When using software iscsi we should be using the existing
configuration from the system for the time being.

References: bnc#884768
Patch: 0095

Avoid bad ip route call on empty address
Patch: 0143

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Hannes Reinecke 54e28d79b9 95iscsi: More empty cmdline fixes
This fixes up some 95iscsi/module-setup.sh which might print out empty
commandline files.

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Hannes Reinecke 2e34f38095 95iscsi: Fixup bnx2i offload booting
bnx2i is using a separate iSCSI offload engine with a separate
MAC address. As a result, the iBFT information is displaying
a MAC address which does not relate to any MAC address from
the network interfaces.
In addition, the iSCSI offload engine works independently on
the NIC, so we do not need to enable the NIC for iSCSI offload
to work.
This patch modifies the automatic iBFT detection to not set
the 'ip=ibft' flag when bnx2i offload is detected.

References: bnc#855747

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Hannes Reinecke 9ebf4a5d3c 95iscsi: strip one set of quotes when calling initqueue
The bad initqueue parameter passing is already addressed by git commit:
commit bb8c16d121
and
commit 486a8f33e2

However this appraoch is slightly different:
"$netroot" instead of "'$netroot'", etc.

initqueue will process the arguments, assuming the first non-option
argument to be the program to be executed. Putting the entire
commandline into this argument confuses both, initqueue and the
program in question.

References: bnc#879038

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:36 +01:00
Hannes Reinecke a3a2266046 95iscsi: Set correct iscsi_started value for iSCSI firmware
When iSCSI firmware booting is selected we should not rely on
'netroot' or 'iscsiroot' variables to be set.

References: bnc#873448

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:35 +01:00
Hannes Reinecke 4aad3438f7 95iscsi: Install libgcc_s library
iscsiuio is using pthread, which requires libgcc_s for
pthread_cancel to work.
Without this library iscsiuio will crash with SIGABRT.

References: bnc#881692

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:35 +01:00
Hannes Reinecke 442abd16d2 95iscsi: Autodetect iSCSI firmware
Some iSCSI initiator present firmware information in
/sys/firmware/ibft or /sys/firmware/iscsi_bootX

Whenever we detect one of those directories we should assume
that the iSCSI devices should be activated.

Also incorporates SUSE patches:
0049:
95iscsi: Use 'ip=ibft' for ibft autoconfiguration

For iBFT autoconfiguration we should be setting 'ip=ibft'
instead of rd.neednet. This should instruct dracut to only
enable the iBFT interfaces and leave the rest alone.

References: bnc#879038

0054:
95iscsi: update commandline printing

dracut has a separate callout 'cmdline' which should be used
for printing out the generated commandline.

Signed-off-by: Pavel Wieczorkiewicz <pwieczorkiewicz@suse.com>
Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:35 +01:00
Hannes Reinecke 8f4ee8c71b 90multipath: install correct multipath rules
The multipath and kpartx rules have different numbers in SUSE.

The 11-dm-mpath.rules file had been missing, causing
blacklisting to not work properly.

References: bnc#873151, bnc#872662, bnc#883149

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:35 +01:00
Hannes Reinecke 15eed1e4f1 95udev-rules: Include correct sg3_utils rules
sg3_utils now provides two rules 55-scsi-sg3_id.rules and
58-scsi-sg3_symlink.rules, which need to be included instead
of the older 59-scsi-sg3_utils.rules.

References: bnc#873151

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:35 +01:00
NeilBrown 36894743e3 Fixup mdraid setup
This sed script to edit 64-md-raid-assemble.rules needs to
be adjusted for latest mdadm

References: bnc#866660

Signed-off-by: NeilBrown <neilb@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:35 +01:00
Thomas Renninger ae8e6ed5af systemd always tries to load autofs4
During boot systemd tries to load autofs4, but dracut will only
add it if it's loaded by the time dracut is run.
Modify dracut to always load autofs4.

References: bnc#869411

Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:35 +01:00
Thomas Renninger 552c37e156 mkinitrd-suse: Update to sles12 SUSE state
Incorporates these patches:
- 0013 mkinitrd-suse: do not update bootloader if no kernel was found
  bnc#858268
- 0018 mkinitrd-suse: Fix whitespaces when adding drivers
- 0032 mkinitrd-suse.sh: Use '--hostonly' and '--hostonly-cmdline' correctly
  bnc#874000,bnc#874905,bnc#874363
- 0039 Remove --force parameter from mkinitrd
- 0041 mkinitd-suse: remove --hostonly and --hostonly-cmdline
  Should be set via configuration files, not in the script itself.
- 0051 mkinitrd-suse: add 'update bootloader' message
- 0120 mkinitrd-suse.sh: Bail out with exit 1 if initrd cannot be generated
  bnc#886630

Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-12-16 13:29:35 +01:00
Harald Hoyer 1f8abe81a9 dmsquash-live: setup the images in /run/initramfs
We want to cleanup / after switch_root. Placing the loop files in /
works, but it is more sane to put them in /run/initramfs
2014-12-16 12:53:18 +01:00
Harald Hoyer 25b987fed6 Fixed the dracut-shutdown.service
Make the service a oneshot service, which remains after exit. This
ensures, that the ExecStop is executed later on, if a shutdown occurs.
2014-12-08 11:32:26 +01:00
Harald Hoyer 414dc51ca2 dracut.conf.d/fedora.conf.example: turn on early_microcode 2014-12-04 11:54:47 +01:00
Tom Gundersen ca4108b78e initrd-release: move from /etc to /usr/lib
This mimicks the similar move of os-release which was done in systemd. These
files are not configuration, but part of the OS.

Still symlinks are in place for compatibility, but those should probably be
dropped eventually.
2014-12-01 17:02:16 +01:00
Minfei Huang c440d302f1 40network: Fix the syntax to correct the judgment sentence
In the judgment sentence, it will print the following warning message,
becasuse of lacking the blank on the left of ']'.

/lib/net-lib.sh: line 110: [: missing `]'

Signed-off-by: Minfei Huang <mhuang@redhat.com>
2014-12-01 17:02:15 +01:00
Harald Hoyer 3ae03005b8 cms/cms-write-ifcfg.sh: turn SUBCHANNELS into lowercase 2014-12-01 15:04:53 +01:00
Harald Hoyer 99d4fd6bb7 do not symlink /var/log to /run/log
some programs e.g. systemd-journald expect a directory in /var/log as
the marker to do some actions. Here journald tries to flush
/run/log/journal to /var/log/journal, if the directory is seen.

/var/log is now a symlink to /run/initramfs/log.
2014-12-01 12:36:20 +01:00
Harald Hoyer 3a04bddeed dracut.sh: add $tmpfilesdir to install files to /usr/lib/tmpfiles.d 2014-12-01 12:34:54 +01:00
Harald Hoyer fa45d0d9c9 base/init.sh: ignore exclamation mark for kmod static-nodes
newer versions add an exclamation mark for the type, to mark it to be
created on boot only.
2014-12-01 11:50:00 +01:00
Harald Hoyer 3659d64df3 fips: add libfreeblpriv3.so and libfreeblpriv3.chk 2014-11-28 15:32:17 +01:00
Harald Hoyer 370035d561 dmsquash-live: do not abort, if user pressed ESC on checkisomd5
If the user pressed ESC while checkisomd5 runs the media check, it will
exit with "2". Previously that would mean, that the media check was not
successful.
2014-11-25 13:44:54 +01:00
Harald Hoyer 2b2033e561 multipath/multipathd.service: add more Conditions
Do not start multipathd on rd.multipath=0 rd_NO_MULTIPATH and if there
is no multipath.conf.
2014-11-25 13:23:21 +01:00
Hannes Reinecke 78a78e4239 90multipath: install dracut-specific service file
The multipathd package might install a service and a socket
file. Using the original service file from the installed
system without the socket file triggers a bug in systemd,
causing systemd to crash.

As we don't actually need to socket file in the initrd we
should be installing our own service file which does not
reference the socket file at all.

References: bnc#871610

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-11-25 13:21:03 +01:00
Hannes Reinecke 856f8265aa 90multipath: Load device_handler modules early during boot
The device handler modules need to be loaded early during boot
to avoid I/O errors being printed to the system log.

References: bnc#871617

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Thomas Renninger <trenn@suse.de>
2014-11-25 13:21:03 +01:00