# On POWER this patch also fixes test-ildoubl and test-ldouble failures where tan |
|
# rounded toward zero had acceptable 1 ULP error. Upstream is using 3 ULP, but |
|
# we prefer to keep the bound tighter unless we have a reason not to. |
|
# |
|
# This is the ppc64le version which is required becuase it applies *after* another |
|
# ppc64le patch that touches the same ULPs file. See glibc-power-libm-test-ulps.patch |
|
# for the ppc64/ppc version. |
|
# |
|
diff -urN glibc-2.17-c758a686/sysdeps/powerpc/fpu/libm-test-ulps glibc-2.17-c758a686/sysdeps/powerpc/fpu/libm-test-ulps |
|
--- glibc-2.17-c758a686/sysdeps/powerpc/fpu/libm-test-ulps 2014-07-25 22:07:06.280020855 -0400 |
|
+++ glibc-2.17-c758a686/sysdeps/powerpc/fpu/libm-test-ulps 2014-07-25 22:26:54.650021033 -0400 |
|
@@ -2644,6 +2644,9 @@ |
|
Test "tan_towardzero (2)": |
|
ildouble: 1 |
|
ldouble: 1 |
|
+Test "tan_towardzero (2) == -2.1850398632615189916433061023136825434320": |
|
+ildouble: 1 |
|
+ldouble: 1 |
|
Test "tan_towardzero (3) == -0.1425465430742778052956354105339134932261": |
|
float: 1 |
|
ifloat: 1
|
|
|