Hello, This patch adds labels for these Dell PowerEdge Servers: R610,R/T710, R220, R/T620, R720/xd, R730/xd, M520, M620 and M820. The current T610 (0F5XM3) mapping is incorrect. This patch fixes it. Reqest review and inclusion to git repo. Acked-by: Aristeu Rozanski Signed-off-by: Charles Rose --- Changes in v2: - Include T110 II, T20, R/T320, M420, R/T420, R/T630, FC620, FC420 - Include additional model numbers for M820 and some 2-socket systems. - Consolidate systems with similar maps. --- labels/dell | 86 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++----- 1 file changed, 79 insertions(+), 7 deletions(-) diff --git a/labels/dell b/labels/dell index e1a09a7..d7e797b 100644 --- a/labels/dell +++ b/labels/dell @@ -9,12 +9,84 @@ # Vendor: Dell Inc. +#### 11G #### +# 2-socket +# PowerEdge R610 + Model: 0K399H, 0F0XJ6 + DIMM_A1: 0.0.0; DIMM_A2: 0.0.1; DIMM_A3: 0.0.2; + DIMM_A4: 0.1.0; DIMM_A5: 0.1.1; DIMM_A6: 0.1.2; - Model: 0F5XM3 - DIMM_A1: 0.0.0; DIMM_A2: 0.0.1; DIMM_A3: 0.0.2; DIMM_A4: 0.0.3; - DIMM_A5: 0.1.0; DIMM_A6: 0.1.1; DIMM_A7: 0.1.2; DIMM_A8: 0.1.3; - DIMM_A9: 0.2.0; DIMM_A10: 0.2.1; DIMM_A11: 0.2.2; DIMM_A12: 0.2.3; + DIMM_B1: 1.0.0; DIMM_B2: 1.0.1; DIMM_B3: 1.0.2; + DIMM_B4: 1.1.0; DIMM_B5: 1.1.1; DIMM_B6: 1.1.2; - DIMM_B1: 1.0.0; DIMM_B2: 1.0.1; DIMM_B3: 1.0.2; DIMM_B4: 1.0.3; - DIMM_B5: 1.1.0; DIMM_B6: 1.1.1; DIMM_B7: 1.1.2; DIMM_B8: 1.1.3; - DIMM_B9: 1.2.0; DIMM_B10: 1.2.1; DIMM_B11: 1.2.2; DIMM_B12: 1.2.3; +# PowerEdge T710 R710 + Model: 01CTXG, 0N0H4P, 0MD99X, 0N047H, 0PV9DG + DIMM_A3: 0.0.0; DIMM_A2: 0.1.0; DIMM_A1: 0.2.0; + DIMM_A6: 0.0.1; DIMM_A5: 0.1.1; DIMM_A4: 0.2.1; + DIMM_A9: 0.0.2; DIMM_A8: 0.1.2; DIMM_A7: 0.2.2; + + DIMM_B3: 1.0.0; DIMM_B2: 1.1.0; DIMM_B1: 1.2.0; + DIMM_B6: 1.0.1; DIMM_B5: 1.1.1; DIMM_B4: 1.2.1; + DIMM_B9: 1.0.2; DIMM_B8: 1.1.2; DIMM_B7: 1.2.2; + +#### 12/13G #### +# 1-socket +# PowerEdge R220 + Model: 081N4V + DIMM_A1: 0.0.0; DIMM_A2: 0.0.1; + DIMM_A3: 0.1.0; DIMM_A4: 0.1.1; + +#PowerEdge T110 II, T20 + Model: 0PC2WT, 0PM2CW, 015TH9, 0MDHN4, 0VD5HY + DIMM_A1: 0.0.0; DIMM_A2: 0.1.0; + + DIMM_B1: 0.0.1; DIMM_B2: 0.1.1; + +#PowerEdge R320 T320 + Model: 0YCV59, 0Y97HY, 07DKYR, 0VJ84C, 07MYHN, 04DMNN, 0W7H8C, 0K20G5, 0V719V, 0FDT3J + DIMM_A1: 0.0.0; DIMM_A2: 0.1.0; DIMM_A3: 0.2.0; + DIMM_A4: 0.0.1; DIMM_A5: 0.1.1; DIMM_A6: 0.2.1; + +# 2-socket +# PowerEdge R620/T620 R720/xd R730/xd T630 R730 R630 T620 M620, FC620 + Model: 0VWT90, 07NDJ2, 0F5XM3, 0PXXHP, 0X3D66, 061P35, 0H5J4J, 00W9X3, 0599V5, 0W9WXC, 0599V5, 0H21J3, 0CNCJW, 02CD1V, 0T5TFW, 0F5XM3, 0G1CNH, 05YV77, 0PDCCX, 093MW8, 0NJVT7 + DIMM_A1: 0.0.0; DIMM_A2: 0.1.0; DIMM_A3: 0.2.0; DIMM_A4: 0.3.0; + DIMM_A5: 0.0.1; DIMM_A6: 0.1.1; DIMM_A7: 0.2.1; DIMM_A8: 0.3.1; + DIMM_A9: 0.0.2; DIMM_A10: 0.1.2; DIMM_A11: 0.2.2; DIMM_A12: 0.3.2; + + DIMM_B1: 1.0.0; DIMM_B2: 1.1.0; DIMM_B3: 1.2.0; DIMM_B4: 1.3.0; + DIMM_B5: 1.0.1; DIMM_B6: 1.1.1; DIMM_B7: 1.2.1; DIMM_B8: 1.3.1; + DIMM_B9: 1.0.2; DIMM_B10: 1.1.2; DIMM_B11: 1.2.2; DIMM_B12: 1.3.2; + +# PowerEdge M520 R420 T420 + Model: 0NRG83, 0DW6GX, 03WPHJ, 06HTRX, 0H1Y24, 02T9N6, 0TT5P2, 0CPKXG, 03015M, 061VPC, 0PC9H0, 0K3G34, 0PC0V5, 08NVYK + DIMM_A1: 0.0.0; DIMM_A2: 0.1.0; DIMM_A3: 0.2.0; + DIMM_A4: 0.0.1; DIMM_A5: 0.1.1; DIMM_A6: 0.2.1; + + DIMM_B1: 1.0.0; DIMM_B2: 1.1.0; DIMM_B3: 1.2.0; + DIMM_B4: 1.0.1; DIMM_B5: 1.1.1; DIMM_B6: 1.2.1; + +#PowerEdge FC420, M420 + Model: 0DPJGD, 068CTP, 0MN3VC, 0417VP + DIMM_A1: 0.0.0; DIMM_A2: 0.1.0; DIMM_A3: 0.2.0; + + DIMM_B1: 1.0.0; DIMM_B2: 1.1.0; DIMM_B3: 1.2.0; + +# 4-socket +# # PowerEdge M820 + Model: 0RN9TC, 0YWR73, 066N7P, 0PFG1N, 0JC2W3 + DIMM_A1: 0.0.0; DIMM_A2: 0.1.0; DIMM_A3: 0.2.0; DIMM_A4: 0.3.0; + DIMM_A5: 0.0.1; DIMM_A6: 0.1.1; DIMM_A7: 0.2.1; DIMM_A8: 0.3.1; + DIMM_A9: 0.0.2; DIMM_A10: 0.1.2; DIMM_A11: 0.2.2; DIMM_A12: 0.3.2; + + DIMM_B1: 1.0.0; DIMM_B2: 1.1.0; DIMM_B3: 1.2.0; DIMM_B4: 1.3.0; + DIMM_B5: 1.0.1; DIMM_B6: 1.1.1; DIMM_B7: 1.2.1; DIMM_B8: 1.3.1; + DIMM_B9: 1.0.2; DIMM_B10: 1.1.2; DIMM_B11: 1.2.2; DIMM_B12: 1.3.2; + + DIMM_C1: 2.0.0; DIMM_C2: 2.1.0; DIMM_C3: 2.2.0; DIMM_C4: 2.3.0; + DIMM_C5: 2.0.1; DIMM_C6: 2.1.1; DIMM_C7: 2.2.1; DIMM_C8: 2.3.1; + DIMM_C9: 2.0.2; DIMM_C10: 2.1.2; DIMM_C11: 2.2.2; DIMM_C12: 2.3.2; + + DIMM_D1: 3.0.0; DIMM_D2: 3.1.0; DIMM_D3: 3.2.0; DIMM_D4: 3.3.0; + DIMM_D5: 3.0.1; DIMM_D6: 3.1.1; DIMM_D7: 3.2.1; DIMM_D8: 3.3.1; + DIMM_D9: 3.0.2; DIMM_D10: 3.1.2; DIMM_D11: 3.2.2; DIMM_D12: 3.3.2; -- 1.9.3