Harald Hoyer
71df3c4329
renamed module-info.sh to module-setup.sh
2011-02-02 16:35:18 +01:00
Harald Hoyer
95d2dabc25
replaced check,install,installkernel with module-info.sh
2011-02-02 13:56:03 +01:00
Harald Hoyer
1b434f1ba9
mdraid/parse-md.sh: create new rules, then mv to old one
...
If udevd is already running, then we should assemble the new rules files
in a seperate file first, before calling it *.rules
Resolves: rhbz#595096
2010-12-06 16:12:54 +01:00
Harald Hoyer
fa7ada31d0
new parameter option names with "rd.*" namespace
...
Renamed Options
Here is a list of options, which were used in dracut prior to
version 008, and their new replacement.
rdbreak
rd.break
rd_CCW
rd.ccw
rdcopystate
rd.copystate
rd_DASD_MOD
rd.dasd_mod.dasd
rd_DASD
rd.dasd
rdinitdebug rdnetdebug
rd.debug
rd_NO_DM
rd.dm=0
rd_DM_UUID
rd.dm.uuid
rdblacklist
rd.driver.blacklist
rdinsmodpost
rd.driver.post
rdloaddriver
rd.driver.pre
rd_NO_FSTAB
rd.fstab=0
rdinfo
rd.info
check
rd.live.check
rdlivedebug
rd.live.debug
live_dir
rd.live.dir
liveimg
rd.live.image
overlay
rd.live.overlay
readonly_overlay
rd.live.overlay.readonly
reset_overlay
rd.live.overlay.reset
live_ram
rd.live.ram
rd_NO_CRYPTTAB
rd.luks.crypttab=0
rd_LUKS_KEYDEV_UUID
rd.luks.keydev.uuid
rd_LUKS_KEYPATH
rd.luks.keypath
rd_NO_LUKS
rd.luks=0
rd_LUKS_UUID
rd.luks.uuid
rd_LUKS_UUID
rd.luks.uuid
rd_NO_LVMCONF
rd.lvm.conf
rd_LVM_LV
rd.lvm.lv
rd_NO_LVM
rd.lvm=0
rd_LVM_SNAPSHOT
rd.lvm.snapshot
rd_LVM_SNAPSIZE
rd.lvm.snapsize
rd_LVM_VG
rd.lvm.vg
rd_NO_MDADMCONF
rd.md.conf=0
rd_NO_MDIMSM
rd.md.imsm=0
rd_NO_MD
rd.md=0
rd_MD_UUID
rd.md.uuid
rd_NFS_DOMAIN
rd.nfs.domain
rd_NO_PLYMOUTH
rd.plymouth=0
rd_retry
rd.retry
rdshell
rd.shell
rd_NO_SPLASH
rd.splash
rdudevdebug
rd.udev.debug
rdudevinfo
rd.udev.info
rd_NO_ZFCPCONF
rd.zfcp.conf=0
rd_ZFCP
rd.zfcp
2010-10-28 17:11:27 +02:00
Harald Hoyer
cc02093d69
reformat source code
...
removed tabs and set indention to 4 spaces
added emacs and vi format headers
2010-09-10 15:34:36 +02:00
Amadeusz Żołnowski
f3af7bd66b
use 'type' built-in instead of external cmd 'which' in every Bash script
2010-08-23 11:54:09 +02:00
Harald Hoyer
3122e93350
mdraid: try to start degraded arrays in various ways
2010-08-02 14:18:00 +02:00
Harald Hoyer
21a7b84486
mdraid: remove mdadm.conf on rd_NO_MDADMCONF
2010-08-02 14:18:00 +02:00
Harald Hoyer
d7cc3f2ef5
mdraid: remove "local"
2010-08-02 14:17:59 +02:00
Harald Hoyer
d752c51b90
mdraid: --no-degraded not allowed with -I
2010-08-02 14:17:58 +02:00
Harald Hoyer
b6a7c09070
chmod 0755 *.sh
2010-05-19 09:40:48 +02:00
Andy Lutomirski
a3afcf2a5a
90mdraid dracut-functions: fix md raid hostonly detection
...
check_block_and_slaves looks at slaves but not parents.
2010-05-19 08:13:12 +02:00
Harald Hoyer
56f184310a
mdraid: try to start container childs manually with "mdadm -R"
2010-04-16 17:59:48 +02:00
Harald Hoyer
d8231fa5c2
mdraid: prefer /etc/mdadm.conf over /etc/mdadm/mdadm.conf
...
see https://bugzilla.redhat.com/show_bug.cgi?id=557339
https://bugzilla.redhat.com/show_bug.cgi?id=559073
2010-01-27 15:59:10 +01:00
Philippe Seewer
2e6b98c7f6
All module scripts should have a shebang
2009-11-27 14:07:21 +01:00
Harald Hoyer
8bfed103d8
mdraid: do not cleanup on auto assembly with mdadm.conf
2009-10-01 14:46:14 +02:00
Harald Hoyer
7a34efa5c4
md/dm/lvm: install pre-pivot cleanup hooks only if actually needed
...
- removed dmraid cleanup
- only call lvm cleanup, if no lvm.conf provided
- copy over lvm.conf by default
- add --nolvmconf --lvmconf parameters
2009-09-18 12:20:21 +02:00
Hans de Goede
d6a5b04043
Recognize nodmraid and noiswmd kernel cmdline options
...
Recognize nodmraid and noiswmd kernel cmdline options, for anaconda /
rc.sysinit / mkinitrd compatibility.
2009-09-18 08:58:14 +02:00
Hans de Goede
1de9edc06e
Do not stop / start udev exec-queue around "mdadm -As --run"
...
When assembling containers + embedded arrays from mdadm.conf,
mdadm needs the /dev/md# node for the container to assemble the
arrays within the container. Stopping the udev exec queue, results in
this node not getting created and mdadm failing to online the
arrays within the container.
Not having stop / start udev exec-queue around "mdadm -As --run" should
be safe as the exact same command is run from rc.sysinit without
any queue locking.
2009-09-18 08:15:59 +02:00
Harald Hoyer
0f7e10cef4
mdraid: save state dir for mdmon/mdadm for the real root
2009-09-17 12:13:54 +02:00
Harald Hoyer
24bac034d1
65-md-incremental-imsm.rules: check if md raid is already running
2009-09-16 16:10:09 +02:00
Harald Hoyer
094097fab3
lvm/dm/md: switch from lockfiles to $sys/$devpath/holders/*
...
This is a more sane solution, than ignoring subsequent "change" events.
The only danger is that we could loop, if a lvm scan triggers a broken
md partition, which triggers a broken PV and so on.
Better fix the scanning tools, not to emit change events for devices,
if no action was taken.
2009-09-16 15:34:13 +02:00
Harald Hoyer
1dd5bc3fba
add udevproperty() to dracut-lib and use it
...
newer versions of udev use --property instead of --env
2009-09-16 10:43:50 +02:00
Harald Hoyer
5c3f5746bb
90mdraid/65-md-incremental-imsm.rules: first set initqueue-finished,
...
then initqueue-settled
also introduce md_finished.sh to check for all md activity to be settled
2009-09-15 15:00:25 +02:00
Harald Hoyer
99433dd289
90mdraid: only switch mdmon to new root, if an instance is running
2009-09-15 15:00:23 +02:00
Harald Hoyer
2f02ae9d45
mdraid: add rd_NO_MDADMCONF --mdadmconf --nomdadmconf
...
Copy /etc/mdadm.conf to initramfs (even for non-hostonly) if
mdadmconf="yes" is set in dracut.conf or --mdadmconf is specified on the
dracut command line.
This was done, because there seems _no_ sane way to autoassemble md raid
arrays.
also moved rd_NO_MD to an udev ENV
2009-09-15 15:00:18 +02:00
Harald Hoyer
5a8d8dfbb6
switch modules to initqueue-finished
2009-09-15 11:17:22 +02:00
Harald Hoyer
650da7bada
removed initrdargs from parse-*.sh
2009-09-10 17:34:15 +02:00
Harald Hoyer
aa297ca6b6
65-md-incremental-imsm.rules: refine rules
2009-09-08 15:33:19 +02:00
Harald Hoyer
f25c9697f8
mdraid: stop udev queue until mdraid assembled
2009-09-08 15:30:17 +02:00
Harald Hoyer
3bb5b261c7
65-md-incremental-imsm: add additional check for md-non-containers
2009-09-08 13:42:31 +02:00
Harald Hoyer
273b197d75
added initqueue-settled and refactored code
2009-09-07 19:12:01 +02:00
Harald Hoyer
906dedf4d5
mdraid-cleanup: do not stop mdraid container
2009-09-07 19:12:00 +02:00
Harald Hoyer
587b3497c1
mdraid_start.sh: fixed raid activation
2009-09-07 16:18:12 +02:00
Harald Hoyer
e4dec3d6b6
{crypt,dmraid,lvm,mdraid}: cleanup with pre-pivot 30 and 31
2009-09-03 17:11:57 +02:00
Harald Hoyer
429aa1a2c2
mdraid: add grep for convenience
2009-09-03 17:11:03 +02:00
Harald Hoyer
52168b7b9d
reordered blkid/vol_id rules
2009-09-02 15:55:34 +02:00
Harald Hoyer
194f7d125f
90*/*cleanup.sh: fixed redirection to /dev/null
2009-09-01 15:59:31 +02:00
Harald Hoyer
780afa9876
release any raid/crypt/lvm device assembled, but not in use
2009-09-01 15:51:51 +02:00
Harald Hoyer
ec74fa8789
split dracut in network / non-network
2009-09-01 15:42:28 +02:00
Harald Hoyer
c1d670a893
65-md-incremental-imsm.rules: also check on "change"
2009-09-01 15:42:27 +02:00
Harald Hoyer
f4c36b28f6
mdraid_start: check if raid is already active before trying to run it
2009-09-01 15:42:27 +02:00
Victor Lowther
59c88f499f
Abstract out vol_id vs. blkid usage
...
Since different distros may or may not use vol_id in udev, and blkid
is generally replacing vol_id, abstract them out into a function which
tries to use vol_id first and blkid second, on the assumption that
blkid can take over for vol_id if vol_id is no longer there.
2009-08-19 22:21:07 -05:00
Victor Lowther
7e2b4f8367
Make mdraid checking use common functionality in dracut-functions
2009-08-16 15:29:59 -05:00
Victor Lowther
62bde8ed7e
make mdraid check script really check to see of the rootfs is on an
...
mdraid block device when run in hostonly mode.
2009-08-16 15:29:27 -05:00
Harald Hoyer
345f573546
90mdraid/parse-md.sh: removed bashism
2009-08-04 11:36:06 +02:00
Harald Hoyer
0e77eb3782
dmraid/mdraid: only try to delete partition 1-1024
...
add "--nr 1-1024" to partx, otherwise partx will try to delete
partitions 1-INT_MAX, which takes a long time.
2009-07-23 11:58:24 +02:00
Harald Hoyer
33ee031c4a
dracut: add --kernel-only and --no-kernel arguments
...
--kernel-only
only install kernel drivers and firmware files
--no-kernel
do not install kernel drivers and firmware files
All kernel module related install commands moved from "install"
to "installkernel".
For "--kernel-only" all installkernel scripts of the specified
modules are used, regardless of any checks, so that all modules
which might be needed by any dracut generic image are in.
The basic idea is to create two images. One image with the kernel
modules and one without. So if the kernel changes, you only have
to replace one image.
Grub and the kernel can handle multiple images, so grub entry can
look like this:
title Fedora (2.6.29.5-191.fc11.i586)
root (hd0,0)
kernel /vmlinuz-2.6.29.5-191.fc11.i586 ro rhgb quiet
initrd /initrd-20090722.img
initrd /initrd-kernel-2.6.29.5-191.fc11.i586.img
initrd /initrd-config.img
initrd-20090722.img
the image provided by the initrd rpm
one old backup version is kept like with the kernel
initrd-kernel-2.6.29.5-191.fc11.i586.img
the image provided by the kernel rpm
initrd-config.img
optional image with local configuration files
2009-07-22 15:07:11 +02:00
Harald Hoyer
308b10311c
mdraid: first remove the partitions, then add to the md raid
2009-07-21 15:40:11 +02:00
Harald Hoyer
7045d15460
dmraid/mdraid: use ENV{DEVTYPE} instead of ATTR{partition}
2009-07-21 15:01:41 +02:00